September 2017
Volume 17, Issue 10
Open Access
Vision Sciences Society Annual Meeting Abstract  |   August 2017
Developing a logarithmic Chinese reading acuity chart
Author Affiliations
  • Cong Yu
    Department of Psychology, Peking University
  • Qi-Ming Han
    Department of Psychology, Peking University
  • Ling-Juan Cong
    Department of Psychology, Peking University
  • Lei Liu
    School of Optometry, University of Alabama at Birmingham
Journal of Vision August 2017, Vol.17, 1040. doi:https://doi.org/10.1167/17.10.1040
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Cong Yu, Qi-Ming Han, Ling-Juan Cong, Lei Liu; Developing a logarithmic Chinese reading acuity chart. Journal of Vision 2017;17(10):1040. https://doi.org/10.1167/17.10.1040.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

An individual's reading ability cannot be reliably predicted from his/her letter acuity, contrast sensitivity, and visual field extent. We developed a set of Chinese Reading Acuity Chart (C-READ for short) to assess the reading ability of Chinese readers, based on the collective wisdom of previously published reading acuity charts, especially the Minnesota Low-Vision Reading Test and the Radner Reading Charts. The C-READ consists of three charts. Each is made of sixteen 12-character Simplified Chinese sentences crafted from 1st-3rd grade textbook materials. Thirty Chinese college students tested the reliability of C-READ with corrected vision. Another thirty-two students validated the C-READ with the International Reading Speed Test (IReST) with corrected- and uncorrected-near vision. The reading acuity, critical print size, and maximum reading speed for young normal native Chinese-speaking readers were 0.16 ± 0.05 logMAR, 0.24 ± 0.06 logMAR and 273.44 ± 34.37 characters/minute (mean ± SD), respectively. The reliability test revealed no significant differences of reading acuity, critical print size, and maximum reading speed among three C-READ charts and no significant test order effect. Regression analyses showed that the maximum reading speed of C-READ could reliably predict the IReST reading speed with corrected near vision (adjusted R2 =0.72). Moreover, the maximum reading speed and the critical print size could together reliably predict IReST reading speed with uncorrected near vision (adjusted R2 = 0.69). The C-READ is a reliable and valid clinical instrument for quantifying reading performance in simplified Chinese readers.

Meeting abstract presented at VSS 2017

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×