Figure 1A depicts the stimulus and task. A gray spot increment (Goldmann III size) was displayed monocularly on a gray background (10 cd/m
2) for 200 ms, in one of two time intervals separated by 500 ms (temporal 2-AFC). Subjects indicated which interval contained the spot, and whether they were “absolutely certain” regarding their choice of interval (see flow chart in
Figure 1B). The 2-AFC paradigm was chosen (as opposed to a Yes/No paradigm) to provide a criterion-free threshold measure for performance, for comparison to the potentially criterion-dependent certainty data.
The method of constant stimuli (MOCS) was used to capture the shape of the psychometric functions. There were seven discrete intensities tested 40 times each. One run, testing a single eccentricity, took approximately 10 minutes. Longer run times were predicted to degrade responses because of fatigue; hence, it was deemed undesirable to test multiple eccentricities in a single run.
During each MOCS run, stimuli were displayed at one of four quadrants positioned symmetrically a fixed distance from fixation (a white cross 1 arc min thick). This spatial uncertainty was introduced to remove any incentive for shifting fixation, given that only a single eccentricity would be tested in each run. Accordingly each block of 40 trials referred to above represents the pooling of data from 10 trials in each of the four quadrants, forming a single block of 40 responses for a given distance from fixation (i.e., responses are averaged across the direction from fixation). Combining spot locations in this way could broaden the slopes measured; to assess this we repeated all analyses with one hemifield removed in either the horizontal or vertical direction and observed that the significance of statistical associations presented in the Results did not change (analysis not shown for brevity).
To decide on the set of stimulus intensities for each subject at a given eccentricity, initial Bayesian testing (ZEST, 40 trials) was conducted to estimate threshold. Based on the fitted psychometric function, 7 test intensities were selected targeting the frequency-of-seeing curve between 2.5% to 97.5% (with equal spacing between intensities in log-contrast space). If the MOCS run subsequently obtained did not reach at least 80% correct at the highest test intensity, a curve was fit to the data and used to suggest a new set of test intensities (again, spanning 2.5% to 97.5% correct). This process was repeated as needed, producing 1 to 3 MOCS runs per subject at each eccentricity. All data were utilized for curve fitting, because even the preliminary runs provide useful information on the asymptotes of the psychometric function.
For the 3°, 3° point, three of five subjects displayed sensitivity for the 200 ms stimuli greater than was allowed by the bit depth of the monitor control (nine bits), so that seven unique MOCS intensities could not be generated. In these subjects the stimulus duration was reduced from 200 ms to 16.7 ms (a single frame), effectively lowering their sensitivity to allow sufficient bit-depth at this location. Results from the other two subjects at this eccentricity were not included for analysis (i.e.,
Figure 2a and
Figure 3a show data from three subjects rather than five).
To facilitate comparison to other work, where possible conditions were chosen to approximate those of the Humphrey Field Analyzer (HFA) (Zeiss, Oberkochen, Germany): the spot size (Goldmann III), stimulus duration (200 ms), background intensity (10 cd/m2), testing distance (300 mm), and eccentricities selected (x°–y° from fixation: 3°–3°, 9°–9°, 15°–15°, and 27°–3°) were all chosen in this way. It should be noted that due to the symmetric spot configuration, 2 of the 4 test locations for the 27-3 eccentricity do not correspond to the HFA, which tests this eccentricity only in the nasal visual field. We also used a central fixation target as does the HFA, although our was a white cross subtending 1°, and 1 arc min thick.