Tinted filters are often used in photography to alter the color appearance of images. It has also been hypothesized (e.g.,
Simunovic et al., 2012) that intraocular filters, such as blue-light filtering intraocular lenses (BLF IOLs) or lenticular or retinal macular pigments (MPs) have the potential to alter color perception.
Bornstein (1973) argued, for example, that semantic differences in basic color terminology across cultures might be explained by group differences in average MP levels. Bornstein hypothesized that the high MP levels of some groups (e.g., individuals near the tropical equator who have a high intake of carotenoid-rich foods) would cause “a reduction in the perception of blueness.” The increasing yellowness of Claude Monet's lens has often been used as an explanation for the slow disappearance of shorter wave colors in his impressionistic paintings (Steele & O'Leary, 2001). The retinal and lenticular pigments do, in fact, screen the foveal cones from a significant amount of light in the short-wave (SW) end of the visible spectrum (400–500 nm). Further, this amount can dramatically differ between individuals (
Curran Celentano, Burke, & Hammond, 2002). At peak absorbance (460 nm, the dominant wavelength of blue sky light), MP screening (
Hammond, Wooten, & Snodderly, 1997) may vary by more than 1 log unit of optical density (= 0.2 to over 1.3). When one adds SW screening of visible light by the crystalline lens (= 0.9 to over 1.6 at 407) (
Wooten, Hammond, & Renzi, 2007), this creates a situation of fairly dramatic individual differences in the amount of SW light incident on the photoreceptors. Note that, although the eye therefore naturally filters light at 460 nm, the same wavelength associated with peak melatonin suppression (
Rea, Bullough, & Figueiro, 2002), the test lens in this study does not. Nonetheless, empirical data show that these natural individual differences seem to have very little impact on color perception. For example,
Stringham, Hammond, Wooten, and Snodderly, (2006) and Stringham and Hammond (
2007) measured π
1 sensitivity and hue cancellation values in subjects with a wide range of MP density. Comparisons were made both across and within subjects (different locations on the retina, where MPs were either dense or mostly absent, were compared). No relation was found; the visual system presumably increases gain to offset filtering by even the highest levels of MP density. The visual system does not operate like a passive detector; rather, it can adapt to large variations in ambient lighting and compensate for similarly large variations in stable intraocular filters.